Ge-monogram ZIDI240WII User Manual

Browse online or download User Manual for Refrigerators Ge-monogram ZIDI240WII. GE Monogram ZIDI240WII User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
120032
Specification Created 12/07
Listed by
Underwriters
Laboratories
ZIDI240WII
GE Monogram
®
Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Installation Information (in inches)
Installation Space
The cutout depth must be 24"
Both models can be installed flush with stardard cabinetry.
Designed to be built-in only. Cannot be used free-standing.
White case and drawer sides, black vented toekick with
optional stainless steel toekick supplied.
Additional Specifications:
A 120 volt 60Hz., 15 or 20 amp power supply is required. An
individual property grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3-
prong electrical receptacle recessed into the back wall as
shown. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
34-1/2"-35"
24" Min.
23-3/4"
34-1/2"
23-3/4" Stainless Steel
Models
24-7/8" Framed Models
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
Depth Including
Handle:
26" Stainless Steel
Models Only
23-3/4" Min.
Note: If installing between frameless
cabinets, a 1/2" wide filler strip or side panel
may be required. The filler strip will act as a
spacer between the door case and adjacent cabinet
and will prevent interference with cabinet door swing.
The width of the opening must include filler panels.
34-1/2" - 35"
24" Min.
47-1/2" Min.
1-1/2"
Locate Outlets
9"
Max.
10-1/2"
1-1/2"
9"
Max.
10-1/2"
24"
For a complete food storage center, install two Monogram
refrigeration modules side-by-side.
Note: Reversible door swing on wine chillers/reserves and
beverage centers only. See below for combination cutout
dimensions.
Important Note: Products must operate from separate,
properly grounded receptacles.
Note: Additional cutout width may be required for
models with custom panels.
Page view 0
1 2 3

Summary of Contents

Page 1 - ZIDI240WII

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.1

Page 2

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.1

Page 3

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.1

Comments to this Manuals

No comments