ZGU30RSLSSMONOGRAM
30" GAS COOKTOP
Product Specification Revised 2/18
NOTES
INSTALLATION
4 9/16"
(11.6)
19 5/8" (49.8)
Cutout depth
5"(12.7)
18"
(45.7)
min
7/16"
(1.1) min
14 3/4"
(37.5) max
drawer depth
(36" models only)
16"
(40.6) max
28 1/2" (72.4)
Cutout width
Min clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
1 1/2" (3.8) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 "(91.4)
Cabinet base
FRONT VIEW
SIDE VIEW
SIDE VIEW
REAR WALL
Gas
supply
line
TOP VIEW OF CUTOUT
DRAWER
FRONT
12"
(30.5)
Allow 5"
minimum
depth
between the
countertop
and an
enclosure
Rear Wall
Non-Combustible
Combustible
Min. Clearance From
Cutout to Rear Wall
2 7/8" (6.0)
3 7/8" (8.6)
ZGU30R
4 9/16"
(11.6)
19 5/8" (49.8)
Cutout depth
5"(12.7)
18"
(45.7)
min
7/16"
(1.1) min
14 3/4"
(37.5) max
drawer depth
(36" models only)
16"
(40.6) max
28 1/2" (72.4)
Cutout width
Min clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
1 1/2" (3.8) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 "(91.4)
Cabinet base
FRONT VIEW
SIDE VIEW
SIDE VIEW
REAR WALL
Gas
supply
line
TOP VIEW OF CUTOUT
DRAWER
FRONT
12"
(30.5)
Allow 5"
minimum
depth
between the
countertop
and an
enclosure
Rear Wall
Non-Combustible
Combustible
Min. Clearance From
Cutout to Rear Wall
2 7/8" (6.0)
3 7/8" (8.6)
ZGU30R
NOTES
A
Wall coverings, countertop and
cabinets surrounding cooktop
must be able to withstand
temperatures of up to 200ºF.
B
Minimum 30" clearance from
countertop to unprotected
overhead surfaces, when no
ventilation hood or microwave
oven is installed.
C
When using a ventilation
hood or microwave oven
above the cooktop, see hood
or microwave installation
instructions for minimum
overhead clearance dimensions.
D
Minimum 18" of clearance
from countertop to nearest
overhead surface on both
sides of cooktop. Make sure to
include any lighting rail covers
in calculation.
E
Minimum 12" distance from
edge of cutout to adjacent side
wall below upper cabinets.
F
Minimum 12" distance from
of countertop to electrical
junction box. Gas supply line
must be 1" distance from rear
wall of cabinet.
G
Maximum 16" depth of
unprotected overhead surfaces,
when no ventilation hood or
microwave oven is installed.
H
Non-Combustible as defined
in the National Fuel Gas
Code (ANSI Z223.1 Current
Edition). Clearances from non-
combustible materials are not
part of the ANSI Z21.1 scope
and are not certified by UL.
Clearances less than 3 7/8"
must be approved by local
codes and/or the authority
having jurisdiction.
I
For Americans with Disabilities
Act (ADA) forward approach
installation: Minimum 5"
clearance between the top
of the countertop and the
enclosure. The enclosure must
be made of at least 1/4" thick
wood material, and must have
an access panel installed in
order to provide access to the
junction box and hold-down
brackets, and to allow for
service of the cooktop.
For more details refer to the
installation instructions for this
product.
COUNTERTOP CUT-OUT
DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
B
A
C
D
I
E
G
F
H